idesign advanced wavescan studio® system Search Results


90
WaveLight GmbH visx idesign advanced wavescan studiotm system
Patient demographics
Visx Idesign Advanced Wavescan Studiotm System, supplied by WaveLight GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/idesign+advanced+wavescan+studio%C2%AE+system/visx+idesign+advanced+wavescan+studiotm+system/pmc05221655-29-10-17
Average 90 stars, based on 1 article reviews
visx idesign advanced wavescan studiotm system - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Patient demographics

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: Patient demographics

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

FDA indications for use and range used in study

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: FDA indications for use and range used in study

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

( A – C ) Illustrations of the change of mean manifest refractive sphere (MRS) and cylinder over time for Visx iDesign, Alcon Contoura, and Nidek CATz, respectively. Abbreviations: MRS, manifest refractive sphere; preop, preoperative; M, month.

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: ( A – C ) Illustrations of the change of mean manifest refractive sphere (MRS) and cylinder over time for Visx iDesign, Alcon Contoura, and Nidek CATz, respectively. Abbreviations: MRS, manifest refractive sphere; preop, preoperative; M, month.

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

Changes in MSE over time

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: Changes in MSE over time

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

( A ) Measuring percent of eyes achieving UDVA of 20/20 or better by stratified preoperative spherical equivalent. ( B ) Measuring percent of eyes within ±0.5 D of emmetropia by stratified preoperative spherical equivalent. In both graphs, data for Alcon Contoura and Nidek CATz were taken at 3 months and data for Visx iDesign was taken at 6 months postoperatively. Data were only included for sample size above ten. There was no FDA data stratifying Nidek CATz based on preoperative spherical equivalent, and thus, this information was excluded from the Figure. *Indicates P -value was less than 0.05. Fisher’s exact test was used to determine statistical significance. Abbreviations: UDVA, uncorrected distance visual acuity; D, diopter; FDA, US Food and Drug Administration.

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: ( A ) Measuring percent of eyes achieving UDVA of 20/20 or better by stratified preoperative spherical equivalent. ( B ) Measuring percent of eyes within ±0.5 D of emmetropia by stratified preoperative spherical equivalent. In both graphs, data for Alcon Contoura and Nidek CATz were taken at 3 months and data for Visx iDesign was taken at 6 months postoperatively. Data were only included for sample size above ten. There was no FDA data stratifying Nidek CATz based on preoperative spherical equivalent, and thus, this information was excluded from the Figure. *Indicates P -value was less than 0.05. Fisher’s exact test was used to determine statistical significance. Abbreviations: UDVA, uncorrected distance visual acuity; D, diopter; FDA, US Food and Drug Administration.

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

( A ) Measuring percent of eyes achieving UDVA of 20/20 or better by stratified preoperative cylinder. ( B ) Measuring percent of eyes within ±0.5 D of emmetropia by stratified preoperative cylinder. In both graphs, data for Alcon Contoura and Nidek CATz were taken at 3 months and data for Visx iDesign was taken at 6 months postoperatively. Data were only included for sample size above ten. *Indicates P -value was less than 0.05. Fisher’s exact test was used to determine statistical significance. Abbreviations: UDVA, uncorrected distance visual acuity; D, diopter.

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: ( A ) Measuring percent of eyes achieving UDVA of 20/20 or better by stratified preoperative cylinder. ( B ) Measuring percent of eyes within ±0.5 D of emmetropia by stratified preoperative cylinder. In both graphs, data for Alcon Contoura and Nidek CATz were taken at 3 months and data for Visx iDesign was taken at 6 months postoperatively. Data were only included for sample size above ten. *Indicates P -value was less than 0.05. Fisher’s exact test was used to determine statistical significance. Abbreviations: UDVA, uncorrected distance visual acuity; D, diopter.

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

Refractive correction parameters stratified by preoperative cylinder

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: Refractive correction parameters stratified by preoperative cylinder

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques:

CR of the three platforms stratified by preoperative cylinder magnitude. The CR is defined by SIRC/IRC. The measurements were taken at 6 months for Visx iDesign and 3 months for Alcon Contoura and Nidek CATz. Abbreviations: CR, correction ratio; SIRC, surgically induced refraction correction; IRC, intended refraction correction; D, diopter.

Journal: Clinical Ophthalmology (Auckland, N.Z.)

Article Title: Comparison and analysis of FDA reported visual outcomes of the three latest platforms for LASIK: wavefront guided Visx iDesign, topography guided WaveLight Allegro Contoura, and topography guided Nidek EC-5000 CATz

doi: 10.2147/OPTH.S115270

Figure Lengend Snippet: CR of the three platforms stratified by preoperative cylinder magnitude. The CR is defined by SIRC/IRC. The measurements were taken at 6 months for Visx iDesign and 3 months for Alcon Contoura and Nidek CATz. Abbreviations: CR, correction ratio; SIRC, surgically induced refraction correction; IRC, intended refraction correction; D, diopter.

Article Snippet: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan StudioTM System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final FitTM Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Techniques: